+226 70 22 81 53 / +226 76 60 15 00
Fast delivery
FR EN
FR EN

Laboratory Gas Piping System

High-purity distribution networks for analytical laboratories, research centers and pharmaceutical industries

Analytical Purity and Precision

Designing a laboratory involves making crucial decisions, particularly regarding the distribution and management of your gases and cryogenic equipment. Make the wise choice of working with an expert partner who fully masters gas distribution and laboratory design.

At every step, we support you through every aspect of your project and help you identify improvements, even for the most complex systems.

We work with your design team to develop the best gas distribution and management systems for your clients. Call on us for:

● Layout of your facility/laboratory's gas distribution
● Advice and design of a risk-based central gas supply
● Detailed assessment of specialty gas equipment needs
● Material selection for equipment and piping
● Sizing of equipment and containers
Safety guidance and safety management review

Whether you are looking for a new design or the modernization of an existing laboratory, we will work hand in hand with you to create the ideal system to ensure operational performance, safety and compliance with standards. From specifying purity levels to answering all your technical gas questions, our team has the expertise to help you make informed decisions and identify the right solutions for your project

Analytical Excellence

Analytical-grade gases up to 99.9999% (N60) with controlled contamination for chromatography, spectrometry and trace analysis.

Gas Systems for Laboratories

High-purity solutions tailored to every analytical technique

📊
Chromatographie GC/LC
High-purity carrier gases
ULTRA-PURE N60
Specialized system to supply chromatographs with ultra-pure carrier gases. Strict impurity control to ensure analytical sensitivity and repeatability.

Chromatography Specifications

  • Helium N60 ≥ 99.9999%
  • Hydrogen N60 ≥ 99.9999%
  • Nitrogen N60 ≥ 99.9999%
  • O2 + H2O ≤ 0.5 ppm
  • Total hydrocarbons ≤ 0.1 ppm

Applications

GC-MS
GC-FID
HPLC
UHPLC
LC-MS
ECD detectors
Spectrometry
Gases for spectrometers
SPECTRO GRADE
Specialized gas distribution for atomic spectrometry, ICP-MS, and elemental analysis. Exceptional purity for trace detection.

Spectrometry Specifications

  • Argon N60 ≥ 99.9999%
  • Acetylene N25 ≥ 99.5%
  • Nitrous Oxide N20 ≥ 99.0%
  • Heavy metals ≤ 0.01 ppm
  • Particles ≤ 0.1 µm

Applications

ICP-MS
ICP-OES
Flame AA
Graphite furnace AA
MS-MS
TOF-MS
Controlled Atmosphere
Inert gases and blends
PURE ATMOSPHERE
Systems for glove boxes, inert enclosures and controlled atmospheres. Protection against oxidation and humidity for sensitive handling.

Atmosphere Specifications

  • Nitrogen N50 ≥ 99.999%
  • Argon N50 ≥ 99.999%
  • Residual oxygen ≤ 2 ppm
  • Humidity ≤ 3 ppm
  • Hydrocarbons ≤ 0.5 ppm

Applications

Glove boxes
Inert enclosures
Organic synthesis
Organometallic chemistry
Sample storage
Equipment purging
On-Site Generators
Autonomous production
LOCAL PRODUCTION
Integrated generators for on-site production of hydrogen, zero air and high-purity nitrogen right in the lab. Guaranteed autonomy and savings.

Generator Specifications

  • Generated hydrogen ≥ 99.999%
  • Zero air ≤ 0.1 ppm THC
  • PSA nitrogen ≥ 99.5%
  • Continuous flow rate 0-2000 mL/min
  • Outlet pressure 0-8 bars

Applications

GC-FID
GC-MS
H2 Generator
Synthetic air
Nitrogen generator
TOC analyzers

Analytical Quality Control

Fromair implements quality control protocols specific to analytical applications, with continuous purity monitoring and performance validation according to laboratory standards.

Every installation is equipped with monitoring systems that detect any quality drift and ensure full traceability of analyses.

Online Analyzers

Continuous monitoring of O2, H2O, CO, CO2 and total hydrocarbons

📊

Data Logging

Full traceability with history and automatic alerts

Method Validation

Performance testing according to ISO 17025 and GLP standards

Certificates of Analysis

Complete documentation for audits and accreditations

Quality Assurance

ISO 9001 quality system with laboratory-specific procedures. Certification of analytical methods and validation of measurement equipment.

Supported Analytical Techniques

Specialized gases for all laboratory applications

Gas Chromatography
GC, GC-MS, GC-MS/MS with ultra-pure carrier gases and auxiliary gases
Required Gases:
  • • Helium N60 (carrier)
  • • Hydrogen N60 (FID)
  • • Zero air (FID)
  • • Nitrogen N50 (make-up)
Atomic Spectrometry
ICP-MS, ICP-OES, flame AA and graphite furnace for elemental analysis
Required Gases:
  • • Argon N60 (plasma)
  • • Acetylene N25 (flame)
  • • Nitrous Oxide N20 (flame)
  • • Argon N50 (purge)
Liquid Chromatography
HPLC, UHPLC, LC-MS with degassing and inert atmosphere
Required Gases:
  • • Nitrogen N50 (degassing)
  • • Helium N50 (ELSD)
  • • Compressed air (nebulization)
  • • Argon N50 (CAD)
TOC/TN Analysis
Total organic carbon and total nitrogen with specialized carrier gases
Required Gases:
  • • Oxygen N50 (combustion)
  • • Nitrogen N50 (carrier)
  • • Zero air (combustion)
  • • CO2 standard (calibration)
💨
Gas Analysis
Permanent gas GC, O2, CO, CO2, THC analyzers
Required Gases:
  • • Helium N60 (carrier)
  • • Hydrogen N60 (FID)
  • • Nitrogen N60 (reference)
  • • Calibration gas mixtures
🌡️
Thermal Analysis
DSC, TGA, DTA with controlled atmospheres and purging
Required Gases:
  • • Nitrogen N50 (inert purge)
  • • Synthetic air (oxidizer)
  • • Argon N50 (purge)
  • • Helium (high conductivity)

Laboratory Installation Specifics

Technical requirements for high-purity installations

Materials and Components

Rigorous material selection to prevent contamination and ensure the purity of analytical gases.

  • Electropolished 316L stainless steel tubing
  • VCR or Swagelok fittings
  • High-purity diaphragm valves
  • 0.01 µm particle filters
  • Moisture and O2 purifiers

🧹 Cleaning Procedures

Cleaning and decontamination protocols specific to ultra-sensitive analytical applications.

  • Complete circuit degreasing
  • Stainless steel surface passivation
  • Helium leak testing
  • Purging and conditioning
  • Final purity validation

📊 Instrumentation and Control

Monitoring and control systems tailored to the strictest analytical requirements.

  • High-precision gauges
  • Ultra-pure pressure regulators
  • Mass flow meters
  • Online purity analyzers
  • Multi-level alarm system

Safety and Compliance

Compliance with laboratory safety standards and environmental regulations.

  • Hydrogen leak detection
  • Gas room ventilation
  • Emergency shutdowns
  • Safety signage
  • User training

Laboratory Gas Project?

Our analytical gas specialists support you in designing your high-purity installation. Personalized study based on your applications and analytical techniques.