Laboratory Gas Piping System
High-purity distribution networks for analytical laboratories, research centers and pharmaceutical industries
Analytical Purity and Precision
Designing a laboratory involves making crucial decisions, particularly regarding the distribution and management of your gases and cryogenic equipment. Make the wise choice of working with an expert partner who fully masters gas distribution and laboratory design.
At every step, we support you through every aspect of your project and help you identify improvements, even for the most complex systems.
We work with your design team to develop the best gas distribution and management systems for your clients. Call on us for:
● Layout of your facility/laboratory's gas distribution
● Advice and design of a risk-based central gas supply
● Detailed assessment of specialty gas equipment needs
● Material selection for equipment and piping
● Sizing of equipment and containers
Safety guidance and safety management review
Whether you are looking for a new design or the modernization of an existing laboratory, we will work hand in hand with you to create the ideal system to ensure operational performance, safety and compliance with standards. From specifying purity levels to answering all your technical gas questions, our team has the expertise to help you make informed decisions and identify the right solutions for your project
Analytical Excellence
Analytical-grade gases up to 99.9999% (N60) with controlled contamination for chromatography, spectrometry and trace analysis.
Gas Systems for Laboratories
High-purity solutions tailored to every analytical technique
Chromatography Specifications
- Helium N60 ≥ 99.9999%
- Hydrogen N60 ≥ 99.9999%
- Nitrogen N60 ≥ 99.9999%
- O2 + H2O ≤ 0.5 ppm
- Total hydrocarbons ≤ 0.1 ppm
Applications
Spectrometry Specifications
- Argon N60 ≥ 99.9999%
- Acetylene N25 ≥ 99.5%
- Nitrous Oxide N20 ≥ 99.0%
- Heavy metals ≤ 0.01 ppm
- Particles ≤ 0.1 µm
Applications
Atmosphere Specifications
- Nitrogen N50 ≥ 99.999%
- Argon N50 ≥ 99.999%
- Residual oxygen ≤ 2 ppm
- Humidity ≤ 3 ppm
- Hydrocarbons ≤ 0.5 ppm
Applications
Generator Specifications
- Generated hydrogen ≥ 99.999%
- Zero air ≤ 0.1 ppm THC
- PSA nitrogen ≥ 99.5%
- Continuous flow rate 0-2000 mL/min
- Outlet pressure 0-8 bars
Applications
Analytical Quality Control
Fromair implements quality control protocols specific to analytical applications, with continuous purity monitoring and performance validation according to laboratory standards.
Every installation is equipped with monitoring systems that detect any quality drift and ensure full traceability of analyses.
Online Analyzers
Continuous monitoring of O2, H2O, CO, CO2 and total hydrocarbons
Data Logging
Full traceability with history and automatic alerts
Method Validation
Performance testing according to ISO 17025 and GLP standards
Certificates of Analysis
Complete documentation for audits and accreditations
Quality Assurance
ISO 9001 quality system with laboratory-specific procedures. Certification of analytical methods and validation of measurement equipment.
Supported Analytical Techniques
Specialized gases for all laboratory applications
Required Gases:
- • Helium N60 (carrier)
- • Hydrogen N60 (FID)
- • Zero air (FID)
- • Nitrogen N50 (make-up)
Required Gases:
- • Argon N60 (plasma)
- • Acetylene N25 (flame)
- • Nitrous Oxide N20 (flame)
- • Argon N50 (purge)
Required Gases:
- • Nitrogen N50 (degassing)
- • Helium N50 (ELSD)
- • Compressed air (nebulization)
- • Argon N50 (CAD)
Required Gases:
- • Oxygen N50 (combustion)
- • Nitrogen N50 (carrier)
- • Zero air (combustion)
- • CO2 standard (calibration)
Required Gases:
- • Helium N60 (carrier)
- • Hydrogen N60 (FID)
- • Nitrogen N60 (reference)
- • Calibration gas mixtures
Required Gases:
- • Nitrogen N50 (inert purge)
- • Synthetic air (oxidizer)
- • Argon N50 (purge)
- • Helium (high conductivity)
Laboratory Installation Specifics
Technical requirements for high-purity installations
Materials and Components
Rigorous material selection to prevent contamination and ensure the purity of analytical gases.
- Electropolished 316L stainless steel tubing
- VCR or Swagelok fittings
- High-purity diaphragm valves
- 0.01 µm particle filters
- Moisture and O2 purifiers
Cleaning Procedures
Cleaning and decontamination protocols specific to ultra-sensitive analytical applications.
- Complete circuit degreasing
- Stainless steel surface passivation
- Helium leak testing
- Purging and conditioning
- Final purity validation
Instrumentation and Control
Monitoring and control systems tailored to the strictest analytical requirements.
- High-precision gauges
- Ultra-pure pressure regulators
- Mass flow meters
- Online purity analyzers
- Multi-level alarm system
Safety and Compliance
Compliance with laboratory safety standards and environmental regulations.
- Hydrogen leak detection
- Gas room ventilation
- Emergency shutdowns
- Safety signage
- User training
Laboratory Gas Project?
Our analytical gas specialists support you in designing your high-purity installation. Personalized study based on your applications and analytical techniques.