+226 70 22 81 53 / +226 76 60 15 00
Fast delivery
FR EN
FR EN

Medical Gas Piping System

Complete medical gas piping systems compliant with international hospital standards

Turnkey Solutions

Fromair designs, installs and maintains complete medical gas distribution systems for hospitals, clinics and care centers. Our installations comply with the latest HTM (Health Technical Memorandum) and ISO standards.

From the preliminary study to commissioning, our specialized technical teams support you through every aspect of your medical piping project, ensuring safety, reliability and regulatory compliance.

Hospital Expertise

More than 50 installations completed in healthcare facilities in Burkina Faso and West Africa. Certification and validation by official bodies.

Our Medical Piping Systems

Technical solutions tailored to all types of healthcare facilities

🫁
Oxygen Network
Central O2 distribution
Complete medical oxygen distribution system from the central source to wall outlets. Installation compliant with hospital safety standards.

Technical Characteristics

  • Degreased medical copper tubing
  • Standardized wall outlets
  • High-precision regulators
  • Integrated alarm system
  • Automatic redundancy
Specifications
Service pressure 4 bars
Max flow rate 60 L/min
Material Medical copper
Standard HTM 02-01
🌪️
Vacuum system
Centralized medical suction
Complete centralized medical suction installation for operating rooms, resuscitation and intensive care units. Guaranteed reliability and safety.

Technical Characteristics

  • Duplex suction plant
  • Safety reservoirs
  • Standardized suction outlets
  • Automatic monitoring
  • Backup system
Specifications
Nominal vacuum -0.75 bar
Flow rate 40 L/min
Reservoir 500-2000L
Power supply 380V three-phase
💨
Medical Air
Compression and filtration
High-quality compressed medical air production and distribution system. Multi-stage filtration and drying for therapeutic applications.

Technical Characteristics

  • Oil-free medical compressors
  • HEPA filtration
  • Refrigerated dryer
  • Buffer tanks
  • Air quality monitoring
Specifications
Pressure 7 bars
Quality Class 1
Humidity ≤ -40°C
Particles ≤ 0.1 µm
😴
N2O Network
Nitrous oxide distribution
Secure installation for distributing nitrous oxide in operating rooms and anesthesia suites. Enhanced safety system.

Technical Characteristics

  • Degreased copper piping
  • Specialized N2O regulators
  • Color-coded outlets
  • Non-return system
  • Safety alarms
Specifications
Service pressure 4.5 bars
Storage Manifold
Safety Dual-stage regulation
Coding N2O Blue

Installation Process

A methodical approach to ensure compliance and safety

1

Study and Design

Needs analysis, feasibility study and detailed design of the medical piping system tailored to your facility.

  • On-site technical visit
  • Flow rate and pressure calculations
  • Detailed installation plans
  • Complete technical quote
2

Procurement

Selection and procurement of materials and equipment compliant with international medical standards.

  • Medically certified materials
  • Equipment from recognized brands
  • Incoming quality control
  • Secure storage
3

Installation

Implementation by certified technicians following hospital safety and hygiene protocols.

  • Qualified technical teams
  • Compliance with hospital protocols
  • Installation without interrupting patient care
  • Network cleaning and degreasing
4

Testing and Validation

Comprehensive performance, tightness and safety testing according to applicable HTM and ISO standards.

  • Tightness testing
  • Flow rate verification
  • Safety testing
  • Validation by an accredited body
5

Training and Commissioning

Training for care and technical staff, delivery of complete documentation and official commissioning.

  • Medical team training
  • User manual
  • Complete technical file
  • Certificate of compliance

Standards and Compliance

Strict compliance with international standards for patient safety

HTM 02-01
Health Technical Memorandum for medical gas systems
Reference British standard for the design, installation and maintenance of medical gas networks
ISO 7396-1
Medical gas distribution systems - Part 1
International standard defining requirements for medical gas piping systems
CEI 60601
Safety of electromedical devices
Electrical safety standards for all connected medical equipment
NFPA 99
Healthcare Facilities Code
American standard for healthcare facility safety
Fire safety and protection requirements for medical gas systems
EN 737
Anesthesia and resuscitation systems
European standards for anesthesia equipment and systems
CE Marking
European compliance
Mandatory CE certification for all installed medical devices

Preventive and Corrective Maintenance

Fromair provides complete maintenance for your medical gas installations with custom contracts that guarantee continuity of care and patient safety.

Our specialized technical team operates on a rigorous preventive schedule and provides 24/7 availability for emergency response.

Preventive Maintenance

Periodic inspections, performance testing, preventive replacement of consumables

Emergency Response

24/7 service for critical failures with technicians permanently on call

📊

Detailed Reports

Complete documentation of interventions and optimization recommendations

Upgrades

Equipment modernization and adaptation to new standards

Service Guarantee

Guaranteed response time under 2h for critical emergencies. Custom contracts including spare parts and ongoing staff training.

Medical Piping Project?

Our specialized engineers support you from design through commissioning of your medical gas systems. Free personalized study and detailed quote.